Aug. 27, 2026
[TL;DR] Hot-dip galvanized PC strand from YUANXIAN XINKE uses a 190–400 g/m² zinc layer (sacrificial anode, ASTM A416 + A475) and fits mild-soil, indoor and medium-exposure bridge members. Epoxy-coated PC strand uses a 0.13–0.30 mm fusion-bonded epoxy barrier (ASTM A882) and wins in chloride-rich sites—coastal piles, de-icing decks, sewage and industrial anchors. Both keep 1860 MPa and ≤2.5% relaxation; the choice is exposure class, not strength. YUANXIAN XINKE stocks both in 12.7 / 15.2 / 15.7 mm dual-certified to ASTM, BS 5896 and GB/T 5224.
Specifying prestressed concrete steel strand is never only about 1860 MPa. The first rejection reason at a coastal or parking-deck job is coating mismatch: galvanized quoted where epoxy was specified, or vice versa. Zinc and epoxy protect by opposite mechanisms—one sacrifices itself, the other blocks everything—so confusing them either burns budget on epoxy where zinc is enough, or invites wire-gap pitting where salt hits an epoxy-scratched strand. This guide compares the two on mechanism, standards, diameter effect, cost and project fit, then shows how YUANXIAN XINKE ships both from Tianjin mill.
YUANXIAN XINKE galvanized 1×7 PC strand in 9.53 / 12.7 / 15.2 / 15.7 mm, zinc 190–400 g/m², winding test 6 turns no peel. Certified ASTM A416 + A475 Class A, BS 5896, GB/T 33363. |
Hot-dip galvanized bonds molten zinc to each of the 7 wires. Zinc corrodes first (sacrificial anode), so a scratch still protects nearby steel—but once the layer depletes in crevices, carbon steel rusts fast in chlorides. Epoxy-coated (fusion-bonded, grit-blasted base) is a non-conductive barrier: 0.13–0.30 mm thick per ASTM A882, optionally fill-coated between wires to kill wire-gap pitting. It does not sacrifice itself; it simply blocks water, O₂ and Cl⁻. Scratches need site repair with compatible epoxy paste.
Zinc layer 190–400 g/m², self-heals small scars, weaker in chloride crevices.
0.13–0.30 mm FBE, blocks Cl⁻ and chemicals, needs cut-end seal and pad sheaves.
Same 1×7 low-relaxation 1860 MPa parent strand, ≤2.5% relaxation, same MBL.
| Parameter | Hot-Dip Galvanized | Epoxy-Coated (FBE) |
|---|---|---|
| Coating thickness | 190–400 g/m² zinc | 0.13–0.30 mm (130–300 µm) |
| Protection mode | Sacrificial anode | Non-conductive barrier |
| Key standard | ASTM A416 + A475, GB/T 33363, BS 5896 | ASTM A882, GB/T 25823, JG/T 387 |
| Chloride (marine/de-icing) | Moderate, crevice limit | Excellent, fill-type seals wire gaps |
| Acid / industrial fume | Fair | Strong (chemical inert) |
| Scratch behavior | Still protects nearby steel | Needs epoxy paste repair |
| Tensile / relaxation | 1860 MPa, ≤2.5%@1000h | 1860 MPa, ≤2.5%@1000h |
| Typical premium vs bare | ~+30–60% | ~+50–90% |
| YUANXIAN XINKE stock | 9.53–15.7 mm | 12.7 / 15.2 / 15.7 mm |
Where galvanized is the right call
| Where epoxy-coated earns its premium
|
YUANXIAN XINKE (Yuanxian High-tech Material Trading, Tianjin) draws, strands, stabilizes and coats in-house—so the parent 1×7 low-relaxation strand is identical before zinc or epoxy is applied. That removes the usual "two mills, two MTC formats" headache. Every coil ships with:
Heat-number MTC (EN 10204 3.1 for BS/EN jobs, ASTM A370 for ASTM jobs)
Coating-weight or coating-thickness test line on the MTC
Relaxation report ≤2.5%@1000h/70%
SGS/BV slot on request, coil tag showing "GALV ASTM A416 15.24" or "FBE A882 15.20"
Capacity ~10,000 t/month ex-Tianjin; stock diameters 12.7 / 15.2 / 15.7 mm in both coatings; 9.53 mm galvanized on call. See all PC strand coatings →
| Epoxy-coated strand from YUANXIAN XINKE uses grit-blasted FBE, optional fill-coat between wires. For external tendons in box girders and marine piles, specify epoxy-coated PC strand with cut-end sealant and padded sheaves. |
Map exposure class—chloride >0.1% or de-icing cycle present → epoxy; mild soil/indoor → galvanized.
Check tendon type—bonded + full grout + 40 mm cover may downgrade galvanized to bare; external PT almost always epoxy.
Confirm standard on BOQ—ASTM A882 for epoxy, ASTM A475 Class A/B + A416 for galvanized, GB/T 25823 or GB/T 33363 for China-funded jobs.
Price the lifecycle, not the coil—epoxy costs more upfront but cuts 20–50% repair cost over 75-yr coastal designs.
A: No. YUANXIAN XINKE re-stress-relaxes the strand after hot-dip galvanizing and verifies on MTC: 1860 MPa tensile, ≤2.5% relaxation at 1000 h. Zinc layer 190–400 g/m² per A475 Class A, winding test 6 turns no peel.
A: FBE adds 0.13–0.30 mm radial build-up. Anchor suppliers must be told the coated diameter (e.g. 15.20 mm bare → ~15.46–15.80 mm coated) so the trumpet and wedge set are matched. YUANXIAN XINKE prints coated OD on the coil tag.
A: Yes. YUANXIAN XINKE produces 15.7 mm super-grade 1860 MPa to BS 5896 in both coatings, with separate MTCs per coil. Mixed 20 ft containers are routine for bridge packages splitting internal (galv) and external (epoxy) tendons.
A: Epoxy-coated 15.2 mm ASTM A416 + A882 is the safer spec; galvanized passes mild exposure but chloride crevice corrosion accelerates at wire gaps. For fully grouted internal tendons with 50 mm cover, galvanized may be accepted—confirm with the structural engineer.
A: Galvanized 12.7/15.2/15.7 mm stock ships 7–10 days ex-Tianjin. Epoxy-coated runs 15–30 workdays (line cure + thickness QA + cut-end seal). Both consolidate into 1–3 containers from 10,000 t/month capacity. Request lead time details →
Galvanized and epoxy-coated PC strand share the same 1860 MPa heart—the split is pure corrosion strategy: zinc sacrifices, epoxy blocks. Pick by exposure class and lifecycle cost, not by habit. YUANXIAN XINKE lets you hold both from one mill with one MTC format, so the engineer keeps the right barrier and procurement keeps one PO.
Get Galvanized & Epoxy PC Strand Quotation →
Principle and Function of Hydrogen Embrittlement Test (HE TEST)
How to Select Prestressed Concrete Steel Wire for Different Structures
Yuanxian High-tech Material is a company serving a worldwide customers base providing innovative and reliable product solution that recognizes the value of customer care.
+86 180 2006 1362
Haitai Huake Third Road No.1, Huayuan Industrial Zone, Binhai High Tech Zone, Tianjin, china
Quick Links
Product Category
Request a Quote
Welcome to subscribe toour email message!
Send a Message